Control charts: choose the correct type

Estimate stability locally from the supplied sequence, with limits and companion plots appropriate to the sample.

Enable Statistical Analysis

For Line, Area or Histogram only, open Analytics → Statistical Analysis. It is Off by default. Line/Area uses the chosen control chart; disabling analysis restores the ordinary chart and its saved settings.

TypeActual inputOther fields / conditions
I–MROne measurement per sampleOrdered Category; adjacent moving ranges
X̄–RRaw measurements or subgroup meansAutomatic n=2–10, raw Observation ID or summary range/sample size
X̄–SRaw measurements or subgroup meansAutomatic/raw/summary input; subgroup SD and n≥2
pDefective units, or configured proportionStatistical sample size; varying n supported
npDefective unitsConstant n; use p when n varies
uDefect countStatistical sample size / exposure; varying exposure
cDefect countEqual inspection exposure

Baseline, tests and limit curves

Choose an inclusive 1-based baseline range, estimated or historical/manual CL/LCL/UCL, sigma multiplier and test rules. LCL and UCL each offer Straight or Stepped display without changing the numerical limits. Companion MR/R/S plots have independent scale semantics.

Individuals and moving-range analysis with estimated limits and summary.

Click to enlarge.

Keep the sequence meaningful

Model order and filters define the sample. Missing observations stay gaps and interrupt moving-range/run sequences. Incomplete loaded data is not analysed until complete. Use an appropriate stable baseline; summary means must be means, not sums.

NIST: X-bar, R and S control charts.

Back to the Knowledge Base

Set an I-MR baseline

Native control-type selection and baseline-window chapter. Other control families have separate examples.

3840 × 2160 tutorial canvas at 20 fps. Real 2560 × 1392 Power BI Desktop screenshots retain their native size; this is a paced step sequence.

  1. Choose a control-chart type — Under Analytics → Statistical Analysis, open Control chart type. Choose the family that matches individual, subgroup or attribute observations.
  2. Select I-MR — The supplied I-MR example uses 150 observations. Its initial center is 67.141; the moving-range companion estimates adjacent variation.
  3. Limit baseline estimation to 1–100 — Set Baseline first sample to 1 and last sample to 100. All 150 points remain plotted, while the baseline center becomes 67.210 and the control limits change.

Download the 4K animated GIF · Download the 4K MP4